Complete Treatment Equipment for Waste Water
of
Printing & Dyeing, Wool Spinning
|
 |
| picture can be enlarged |
|
¡¡¡¡ This equipment is composed of sedimentation tank with sloped pipe, biological contact oxidation tank, TFQ aeration tank etc. Its removal rate of organic substances can be very high. So it is treatment equipment suitable for discharging of various organic sewage and recycling water, widely used for treating various organic waste water and sewage from city, printing & dyeing, wine-making, foodstuff processing, chemical industry, pulp mill etc. After treatment the quality of water can reach the specification stipulated in ¡°National standard for comprehensive discharging of industrial¡®Three wastes¡¯¡±GB8978-88¡£
Technical process:
 |
Main technical data of sedimentation tank by slanting pipe£º
Type |
Capacity(m3/h) |
Overall dimension
(mm) |
Type of pump |
Power rate of pump |
| M2H-5X |
5 |
1500¡Á2000¡Á3500 |
IS50-32-160 |
0.55 |
| M2H-10X |
10 |
2000¡Á3000¡Á4600 |
IS65-50-125 |
0.55 |
| M2H-15X |
15 |
2750¡Á3000¡Á4600 |
IS80-65-125 |
0.75 |
| M2H-20X |
20 |
3500¡Á3000¡Á4600 |
IS80-65-125 |
0.75 |
| M2H-25X |
25 |
4250¡Á3000¡Á4600 |
IS80-65-125 |
0.75 |
| M2H-30X |
30 |
8000¡Á3000¡Á4600 |
IS100-80-125 |
1.5 |
| Note: The equipment applies to treatment of raw water with suspending substance less than 5000mg/L. Other types of pump shall be taken into consideration if height and distance from water collecting tank to sedimentation become larger |
Main technical data of biological contact oxidation unit £º
Type |
Capacity (m3/h) |
Overall dimension(mm) |
Type of pump |
Power rate of pump(kw) |
| M2H-5Y |
5 |
1500¡Á2000¡Á3500 |
LG202¡Á200-1 |
3.0 |
| M2H-10Y |
10 |
4000¡Á3000¡Á4600 |
LG202¡Á200-1 |
3.0 |
| M2H-15Y |
15 |
6000¡Á3000¡Á4600 |
LG202¡Á200-1 |
3.0 |
| M2H-20Y |
20 |
8000¡Á3000¡Á4600 |
LG202¡Á200-1 |
7.5 |
| M2H-25Y |
25 |
10000¡Á3000¡Á4600 |
LG202¡Á200-1 |
7.5 |
| M2H-50Y |
50 |
20000¡Á3000¡Á4600 |
LG300¡Á200-1 |
15 |
| Note: The equipment applies to treatment of organic sewage with BOD5 ranging in 150£300mg/L. Oxidation tank shall be enlarged if concentration of sewage is too high. |
Main technical data of TFQ coagulation air floating unit £º
Type |
Capacity
(t/h) |
Overall dimension
(mm) |
Specification of air dissolving tank (mm) |
Specification of air dissolving pump |
| TFQ-5 |
5 |
¦µ1920¡Á2840 |
Dg400 |
11/2GC-5¡Á2 |
| TFQ-10 |
10 |
¦µ2700¡Á3060 |
Dg400 |
11/2GC-5¡Á2 |
| TFQ-15 |
15 |
¦µ3200¡Á3290 |
Dg400 |
11/2GC-5¡Á2 |
| TFQ-20 |
20 |
¦µ3360¡Á3360 |
Dg600 |
2GC-3 |
| TFQ-25 |
25 |
¦µ4060¡Á3433 |
Dg600 |
2GC-3 |
| TFQ-50 |
50 |
¦µ9500¡Á4000¡Á3000 |
Dg1000 |
21/2GC-2 |
|
|
|
| ------------------------------------------------------------------------------------ |
| TEL :86-510-83581596 ¡¡013706177616 |
|